September 30th, 2008The software version will be listed on the TechniChlor and ColorChlor next to the serial number label. To see what specific changes have been made to the particular unit you have refer to the ColorChlor pages at www.ControlOMatic.com. These changes may not be documented in the owner’s manual.
Software Version 1
Customer Request: Increased the light show time from 10 minutes to 15 minutes. The time off after the light show until chlorine generation will commence is also 15 minutes.
Customer Request: When used in very small SPA’s that are not used very often the ColorChlor makes too much chlorine even at the lowest power level. Turns out that when the ColorChlor is in an off cycle it checks to see if it has been removed from the water in order to start a light show, this checking was making more chlorine than we expected. The checking interval was 1 second and has been increased to 2.5 seconds. The on time was also decreased from 7.5 minutes to 2 minutes and the 1 minute minimum on time has been removed.